Skip to main content

Main menu

  • Home
  • Current Issue
  • Content
    • Current Issue
    • Early Access
    • Multimedia
    • Podcast
    • Collections
    • Past Issues
    • Articles by Subject
    • Articles by Type
    • Supplements
    • Plain Language Summaries
    • Calls for Papers
  • Info for
    • Authors
    • Reviewers
    • Job Seekers
    • Media
  • About
    • Annals of Family Medicine
    • Editorial Staff & Boards
    • Sponsoring Organizations
    • Copyrights & Permissions
    • Announcements
  • Engage
    • Engage
    • e-Letters (Comments)
    • Subscribe
    • Podcast
    • E-mail Alerts
    • Journal Club
    • RSS
    • Annals Forum (Archive)
  • Contact
    • Contact Us
  • Careers

User menu

  • My alerts

Search

  • Advanced search
Annals of Family Medicine
  • My alerts
Annals of Family Medicine

Advanced Search

  • Home
  • Current Issue
  • Content
    • Current Issue
    • Early Access
    • Multimedia
    • Podcast
    • Collections
    • Past Issues
    • Articles by Subject
    • Articles by Type
    • Supplements
    • Plain Language Summaries
    • Calls for Papers
  • Info for
    • Authors
    • Reviewers
    • Job Seekers
    • Media
  • About
    • Annals of Family Medicine
    • Editorial Staff & Boards
    • Sponsoring Organizations
    • Copyrights & Permissions
    • Announcements
  • Engage
    • Engage
    • e-Letters (Comments)
    • Subscribe
    • Podcast
    • E-mail Alerts
    • Journal Club
    • RSS
    • Annals Forum (Archive)
  • Contact
    • Contact Us
  • Careers
  • Follow annalsfm on Twitter
  • Visit annalsfm on Facebook
Research ArticleOriginal ResearchA

Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care

Jelle C.L. Himmelreich, Evert P.M. Karregat, Wim A.M. Lucassen, Henk C.P.M. van Weert, Joris R. de Groot, M. Louis Handoko, Robin Nijveldt and Ralf E. Harskamp
The Annals of Family Medicine September 2019, 17 (5) 403-411; DOI: https://doi.org/10.1370/afm.2438
Jelle C.L. Himmelreich
1Amsterdam UMC, University of Amsterdam, Department of General Practice, Amsterdam Public Health, Amsterdam, The Netherlands
MD, MSc
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: j.c.himmelreich@amc.uva.nl
Evert P.M. Karregat
1Amsterdam UMC, University of Amsterdam, Department of General Practice, Amsterdam Public Health, Amsterdam, The Netherlands
MD, MSc
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wim A.M. Lucassen
1Amsterdam UMC, University of Amsterdam, Department of General Practice, Amsterdam Public Health, Amsterdam, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Henk C.P.M. van Weert
1Amsterdam UMC, University of Amsterdam, Department of General Practice, Amsterdam Public Health, Amsterdam, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joris R. de Groot
2Amsterdam UMC, University of Amsterdam, Department of Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Louis Handoko
3Amsterdam UMC, Vrije Universiteit Amsterdam, Department of Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robin Nijveldt
4Radboud University Medical Center, Department of Cardiology, Nijmegen, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ralf E. Harskamp
1Amsterdam UMC, University of Amsterdam, Department of General Practice, Amsterdam Public Health, Amsterdam, The Netherlands
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • eLetters
  • Info & Metrics
  • PDF
Loading

Abstract

PURPOSE To validate a smartphone-operated, single-lead electrocardiography (1L-ECG) device (AliveCor KardiaMobile) with an integrated algorithm for atrial fibrillation (AF) against 12-lead ECG (12L-ECG) in a primary care population.

METHODS We recruited consecutive patients who underwent 12L-ECG for any nonacute indication. Patients held a smartphone with connected 1L-ECG while local personnel simultaneously performed 12L-ECG. All 1L-ECG recordings were assessed by blinded cardiologists as well as by the smartphone-integrated algorithm. The study cardiologists also assessed all 12L-recordings in random order as the reference standard. We determined the diagnostic accuracy of the 1L-ECG in detecting AF or atrial flutter (AFL) as well as any rhythm abnormality and any conduction abnormality with the simultaneously performed 12L-ECG as the reference standard.

RESULTS We included 214 patients from 10 Dutch general practices. Mean ± SD age was 64.1 ± 14.7 years, and 53.7% of the patients were male. The 12L-ECG diagnosed AF/AFL, any rhythm abnormality, and any conduction abnormality in 23, 44, and 28 patients, respectively. The 1L-ECG as assessed by cardiologists had a sensitivity and specificity for AF/AFL of 100% (95% CI, 85.2%-100%) and 100% (95% CI, 98.1%-100%). The AF detection algorithm had a sensitivity and specificity of 87.0% (95% CI, 66.4%-97.2%) and 97.9% (95% CI, 94.7%-99.4%). The 1L-ECG as assessed by cardiologists had a sensitivity and specificity for any rhythm abnormality of 90.9% (95% CI, 78.3%-97.5%) and 93.5% (95% CI, 88.7%-96.7%) and for any conduction abnormality of 46.4% (95% CI, 27.5%-66.1%) and 100% (95% CI, 98.0%-100%).

CONCLUSIONS In a primary care population, a smartphone-operated, 1L-ECG device showed excellent diagnostic accuracy for AF/AFL and good diagnostic accuracy for other rhythm abnormalities. The 1L-ECG device was less sensitive for conduction abnormalities.

Key words
  • single-lead
  • electrocardiography
  • medical device
  • atrial fibrillation
  • cardiac arrhythmia
  • cardiac conduction system disease
  • cardiac complexes, premature
  • Received for publication December 18, 2018.
  • Revision received April 3, 2019.
  • Accepted for publication April 12, 2019.
  • © 2019 Annals of Family Medicine, Inc.
View Full Text
PreviousNext
Back to top

In this issue

The Annals of Family Medicine: 17 (5)
The Annals of Family Medicine: 17 (5)
Vol. 17, Issue 5
September/October 2019
  • Table of Contents
  • Index by author
  • Back Matter (PDF)
  • Front Matter (PDF)
  • In Brief
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Annals of Family Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care
(Your Name) has sent you a message from Annals of Family Medicine
(Your Name) thought you would like to see the Annals of Family Medicine web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
2 + 17 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care
Jelle C.L. Himmelreich, Evert P.M. Karregat, Wim A.M. Lucassen, Henk C.P.M. van Weert, Joris R. de Groot, M. Louis Handoko, Robin Nijveldt, Ralf E. Harskamp
The Annals of Family Medicine Sep 2019, 17 (5) 403-411; DOI: 10.1370/afm.2438

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Get Permissions
Share
Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care
Jelle C.L. Himmelreich, Evert P.M. Karregat, Wim A.M. Lucassen, Henk C.P.M. van Weert, Joris R. de Groot, M. Louis Handoko, Robin Nijveldt, Ralf E. Harskamp
The Annals of Family Medicine Sep 2019, 17 (5) 403-411; DOI: 10.1370/afm.2438
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • INTRODUCTION
    • METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • eLetters
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Palpitations in athletes: diagnosis, workup and treatment
  • Reliability of single-lead electrocardiogram interpretation to detect atrial fibrillation: insights from the SAFER Feasibility Study
  • NICE atrial fibrillation guideline snubs wearable technology: a missed opportunity?
  • Manual QT interval measurement with a smartphone-operated single-lead ECG versus 12-lead ECG: a within-patient diagnostic validation study in primary care
  • Single-lead ECGs (AliveCor) are a feasible, cost-effective and safer alternative to 12-lead ECGs in community diagnosis and monitoring of atrial fibrillation
  • Diagnostic Accuracy of a Smartphone-Operated Single-Lead ECG for Detection of Rhythm and Conduction Abnormalities in Primary Care
  • Google Scholar

More in this TOC Section

  • Convenience or Continuity: When Are Patients Willing to Wait to See Their Own Doctor?
  • Feasibility and Acceptability of the “About Me” Care Card as a Tool for Engaging Older Adults in Conversations About Cognitive Impairment
  • Treatment of Chlamydia and Gonorrhea in Primary Care and Its Patient-Level Variation: An American Family Cohort Study
Show more Original Research

Similar Articles

Subjects

  • Domains of illness & health:
    • Acute illness
    • Chronic illness
  • Methods:
    • Quantitative methods
  • Other topics:
    • Health informatics

Keywords

  • single-lead
  • electrocardiography
  • medical device
  • atrial fibrillation
  • cardiac arrhythmia
  • cardiac conduction system disease
  • cardiac complexes, premature

Content

  • Current Issue
  • Past Issues
  • Early Access
  • Plain-Language Summaries
  • Multimedia
  • Podcast
  • Articles by Type
  • Articles by Subject
  • Supplements
  • Calls for Papers

Info for

  • Authors
  • Reviewers
  • Job Seekers
  • Media

Engage

  • E-mail Alerts
  • e-Letters (Comments)
  • RSS
  • Journal Club
  • Submit a Manuscript
  • Subscribe
  • Family Medicine Careers

About

  • About Us
  • Editorial Board & Staff
  • Sponsoring Organizations
  • Copyrights & Permissions
  • Contact Us
  • eLetter/Comments Policy

© 2025 Annals of Family Medicine