Skip to main content

Main menu

  • Home
  • Current Issue
  • Content
    • Current Issue
    • Early Access
    • Multimedia
    • Podcast
    • Collections
    • Past Issues
    • Articles by Subject
    • Articles by Type
    • Supplements
    • Plain Language Summaries
    • Calls for Papers
  • Info for
    • Authors
    • Reviewers
    • Job Seekers
    • Media
  • About
    • Annals of Family Medicine
    • Editorial Staff & Boards
    • Sponsoring Organizations
    • Copyrights & Permissions
    • Announcements
  • Engage
    • Engage
    • e-Letters (Comments)
    • Subscribe
    • Podcast
    • E-mail Alerts
    • Journal Club
    • RSS
    • Annals Forum (Archive)
  • Contact
    • Contact Us
  • Careers

User menu

  • My alerts

Search

  • Advanced search
Annals of Family Medicine
  • My alerts
Annals of Family Medicine

Advanced Search

  • Home
  • Current Issue
  • Content
    • Current Issue
    • Early Access
    • Multimedia
    • Podcast
    • Collections
    • Past Issues
    • Articles by Subject
    • Articles by Type
    • Supplements
    • Plain Language Summaries
    • Calls for Papers
  • Info for
    • Authors
    • Reviewers
    • Job Seekers
    • Media
  • About
    • Annals of Family Medicine
    • Editorial Staff & Boards
    • Sponsoring Organizations
    • Copyrights & Permissions
    • Announcements
  • Engage
    • Engage
    • e-Letters (Comments)
    • Subscribe
    • Podcast
    • E-mail Alerts
    • Journal Club
    • RSS
    • Annals Forum (Archive)
  • Contact
    • Contact Us
  • Careers
  • Follow annalsfm on Twitter
  • Visit annalsfm on Facebook
Meeting ReportHypertension

The T-Connector Approach: a simultaneous method for in-office assessment of home blood pressure monitor accuracy

Erin Lloyd, Jennifer Ringrose, Scott Garrison and Bonaventure Oguaju
The Annals of Family Medicine November 2024, 22 (Supplement 1) 7034; DOI: https://doi.org/10.1370/afm.22.s1.7034
Erin Lloyd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jennifer Ringrose
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Scott Garrison
MD, PhD, BASc
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bonaventure Oguaju
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • eLetters
  • Info & Metrics
  • PDF
Loading

Abstract

Context Hypertension Canada recommends home blood pressure monitors (HBPM) for diagnosing and managing hypertension. However, 29% of HBPMs are inaccurate by 10 mmHg or more. This makes determining HBPM accuracy of great clinical importance, but there is no established method of doing so in the office. Serial blood pressure (BP) measurements can be attempted, but a large number is needed to rule out transient changes in BP.

Objective To introduce the novel approach of using a T-Connector between a patient’s HBPM and their physician’s office sphygmomanometer to permit a simultaneous blood pressure reading.

Study Design 89 participants had the accuracy of their personal HBPMs assessed by 1) a family physician using our T-Connector Approach and 2) the gold standard method called Dual Observer Auscultation, which involves 2 physicians alternating between the HBPM and a mercury manometer for 9 readings.

Setting Kaye Edmonton Clinic Family Medicine Clinic and a hypertension research lab.

Population Adults who own a HBPM.

Instrument The T-Connector Approach uses latex tubing, a plastic barbed tee piece, and a metal connector from the primary care clinic (the piece used to switch blood pressure cuffs) to connect a patient’s HBPM to their physician’s office sphygmomanometer.

Outcome Measures an inaccurate HBPM was defined as providing a blood pressure reading ≥ 10 mmHg different than the T-Connector or dual observer auscultation methods. We primarily compared the ability of the T-Connector to detect inaccurate monitors compared to the dual observer auscultation (DOA) gold standard method.

Results Compared to DOA, the T-Connector’s assessment of HBPM error was an average of 2.97 mmHg lower, 95% limits of agreement were -10.72 to 16.65 mmHg, and the intraclass correlation coefficient (ICC) was 0.47. Sensitivity and specificity for detecting an inaccurate monitor were 0.33 and 0.97 respectively, with a positive predictive value (PPV) of 0.75, and a negative predictive value (NPV) of 0.85. Cohen’s kappa was 0.39.

Conclusion Based on the Cohen’s kappa of 0.39 (fair agreement), PPV of 0.75, and NPV of 0.85 there appears to be reasonable utility for using a T-Connector to qualitatively declare a HBPM to be inaccurate for its user. However, the sensitivity was low (0.33) and the ICC being <0.5 indicates poor agreement for quantitative assessment of the mmHg of error.

  • © 2024 Annals of Family Medicine, Inc. For the private, noncommercial use of one individual user of the Web site. All other rights reserved.
Previous
Back to top

In this issue

The Annals of Family Medicine: 22 (Supplement 1)
The Annals of Family Medicine: 22 (Supplement 1)
Vol. 22, Issue Supplement 1
20 Nov 2024
  • Table of Contents
  • Index by author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Annals of Family Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The T-Connector Approach: a simultaneous method for in-office assessment of home blood pressure monitor accuracy
(Your Name) has sent you a message from Annals of Family Medicine
(Your Name) thought you would like to see the Annals of Family Medicine web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
6 + 7 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
The T-Connector Approach: a simultaneous method for in-office assessment of home blood pressure monitor accuracy
Erin Lloyd, Jennifer Ringrose, Scott Garrison, Bonaventure Oguaju
The Annals of Family Medicine Nov 2024, 22 (Supplement 1) 7034; DOI: 10.1370/afm.22.s1.7034

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Get Permissions
Share
The T-Connector Approach: a simultaneous method for in-office assessment of home blood pressure monitor accuracy
Erin Lloyd, Jennifer Ringrose, Scott Garrison, Bonaventure Oguaju
The Annals of Family Medicine Nov 2024, 22 (Supplement 1) 7034; DOI: 10.1370/afm.22.s1.7034
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • eLetters
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Evaluating the Impact of Data Visualization with China-PAR on Hypertension Management in Primary Care: A Pilot Study
  • Association between Hypertension and Sleep Structure Based on Heart Rate Variability
Show more Hypertension

Similar Articles

Content

  • Current Issue
  • Past Issues
  • Early Access
  • Plain-Language Summaries
  • Multimedia
  • Podcast
  • Articles by Type
  • Articles by Subject
  • Supplements
  • Calls for Papers

Info for

  • Authors
  • Reviewers
  • Job Seekers
  • Media

Engage

  • E-mail Alerts
  • e-Letters (Comments)
  • RSS
  • Journal Club
  • Submit a Manuscript
  • Subscribe
  • Family Medicine Careers

About

  • About Us
  • Editorial Board & Staff
  • Sponsoring Organizations
  • Copyrights & Permissions
  • Contact Us
  • eLetter/Comments Policy

© 2025 Annals of Family Medicine